Sign In | Join Free | My benadorassociates.com
China Wuxi Consensic Electronic Technology Co., Ltd. logo
Wuxi Consensic Electronic Technology Co., Ltd.
Wuxi Consensic Electronic Technology Co., Ltd.
Verified Supplier

2 Years

Home > Sensor >

CTS110 Sensor Measurement Range: 0-2MPa High Reliability, Good Stability, And Low Long-Term Drift Large Working Temperature Range:- 20℃~85℃ High

Wuxi Consensic Electronic Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

CTS110 Sensor Measurement Range: 0-2MPa High Reliability, Good Stability, And Low Long-Term Drift Large Working Temperature Range:- 20℃~85℃ High

  • 1
  • 2

Brand Name : Consensic

Model Number : CTS110

Place of Origin : CHINA

MOQ : Please contact us for details

Price : Offline contact or face-to-face discussion can be negotiated

Payment Terms : L/C/Ade/Pellet/Texi Union, MoneyGram, Alipay, and business-to-business payments

Supply Ability : 999

Delivery Time : 3-7 work days

Measuring range : 0~2MPa

accuracy : ±1.0F.S

levels of protection : IP65

christen : CTS110 Measuring range: 0~2MPa Large operating temperature range: -20°C~85°C

Temperature range : -20~+85 ℃

range : 0 ~ 500 KPa, 0 to 700 KPa, 0 to 1 MPa, 0~1.6MPa, 0 to 2 MPa et al

Contact Now

CTS110 Sensor Measurement Range: 0-2MPa High Reliability, Good Stability, And Low Long-Term Drift Large Working Temperature Range:- 20℃~85℃ High Overload Voltage/Current Output

CT1110 is a ceramic capacitor pressure core, high-performance ASIC signal conditioning core, and peripheral circuit package. Within its range, the capacitance is proportional to the pressure and has extremely high linearity. It has excellent compatibility with the vast majority of pressure media, with excellent properties such as corrosion resistance, impact vibration resistance, anti-interference, high reliability, small fixed temperature drift, extremely low hysteresis, and extremely low fatigue. Widely used in the fields of pressure measurement and control, HVAC, automobiles, water pumps, water treatment, etc.

CTS110 Sensor Measurement Range: 0-2MPa High Reliability, Good Stability, And Low Long-Term Drift Large Working Temperature Range:- 20℃~85℃ High

Precautions for use

1. Do not touch the sensor diaphragm with hands or other objects, otherwise the sensor diaphragm will be damaged.
2. The transmitter should not be overloaded, otherwise it will cause the sensitive diaphragm of the sensor to be stressed and deformed and drift. The pressure applied must not exceed the transmission
The maximum overload pressure that the sensor can withstand, otherwise the sensor will be completely damaged.
3. The supply voltage of the transmitter must be less than 36VDC (or the highest voltage indicated on the nameplate), and the high-voltage mains must never be connected to the meter.
4. The transmitter is composed of a circuit, and the sum of the load resistance should be in the working area specified in the instruction manual.

5. It is strictly forbidden to impact, knock and other violent impacts of the transmitter during transportation, installation and use.
6. The transmitter must be used according to the specifications, and the different types are not interchangeable.
7. It is strictly forbidden to overvoltage during testing and use. The transmitter range can be reduced, but it is not allowed to exceed the upper limit of the range. The transmitter is instantaneous
Withstands 1.25 times the upper range of overload pressure; However, if the transmitter is subjected to more pressure than the maximum overload pressure, the transmitter will be damaged.
8. The temperature of the medium in contact with the sensor diaphragm must be within the allowable temperature range; Otherwise, the transmitter will be damaged. below 0°C or special
When measuring the medium, it should be disposed of according to the following requirements after stopping the operation: if the measured liquid remains in the measuring chamber, the liquid will freeze, and as a result
The transmitter can be damaged, so it is necessary to drain the liquid to be tested after the operation has been stopped, or to take antifreeze insulation measures.
9. In order to prevent electromagnetic radiation and lightning attack, the transmitter housing should be grounded and connected by shielded cable.
10. The transmitter should not be used to measure media that are corrosive to ceramic, nitrile and stainless steel.

Parameter

applied range Measurement of pressure in industrial process control systems
Detected media Fluid compatible with ceramic, stainless steel, and nitrile rubber
range 0 ~ 500 KPa, 0 to 700 KPa, 0 to 1 MPa, 0~1.6MPa, 0 to 2 MPa et al
Overload pressure 2 Admito full range
accuracy

1% F.S

operating temperature range -20~+85℃
Storage temperature range -40~+85℃
Compensation temperature range 0 ~ 50℃
Effects of changes in the ambient temperature 0.03% / ℃, a typical value
stability <0.5%FS / year
output Current output 4 ~ 20 m ADC two lines; voltage output 0.5-4.5V
Zero point deviation

1.0% FS

Power Supply Voltage 10 to 36 VDC; 12 to 36 VDC or 5VDC at voltage output
Main material 304, with stainless steel
levels of protection

IP65

CTS110 Sensor Measurement Range: 0-2MPa High Reliability, Good Stability, And Low Long-Term Drift Large Working Temperature Range:- 20℃~85℃ High


Quality CTS110 Sensor Measurement Range: 0-2MPa High Reliability, Good Stability, And Low Long-Term Drift Large Working Temperature Range:- 20℃~85℃ High for sale

CTS110 Sensor Measurement Range: 0-2MPa High Reliability, Good Stability, And Low Long-Term Drift Large Working Temperature Range:- 20℃~85℃ High Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Wuxi Consensic Electronic Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)