| Sign In | Join Free | My benadorassociates.com |
|
Brand Name : Consensic
Model Number : CPG
Place of Origin : WUXI
MOQ : Please contact us for details
Price : Offline contact or face-to-face discussion can be negotiated
Payment Terms : L/C/Ade/Pellet/Texi Union, MoneyGram, Alipay, and business-to-business payments
Supply Ability : 999
Delivery Time : 3-7 work days
zero offset : -15~+15mV
nolinear : 0.2~0.5%FS
stability : %FS /Y
service voltage : 5~10Vdc
CPG Zero Offset -15~+15mV Nolinear 0.2~0.5%FS Stability 0.2 %FS /Y
Note: If not specified, all values in this table are tested at a voltage of 5 Vdc and a temperature of 25 ± 3°C.
| parameter | minimum | typical case | maximum | unit | remarks | |
| service voltage | - | 5 | 10 | Vdc | ||
| supply current | - | 1 | - | mAdc | ||
| range | 10,40,100,700 | kPa | ||||
| Bridge arm resistance | 4.5 | 5 | 5.5 | kΩ | ||
| zero offset | -15 | 0 | +15 | mV | ||
|
full range output |
10kPa | 18 | 23 | 28 | mV | |
| 40Kpa | 50 | 75 | 100 | mV | ||
| 100Kpa /700Kpa | 80 | 100 | 120 | mV | ||
| nolinear | - | 0.2 | 0.5 | %FS | ||
| Zero-point output temperature coefficient, TCO | -0.08 | -0.03 | 0.08 | %FS /℃ | Constant pressure mode | |
| -0.08 | -0.04 | 0.08 | %FS /℃ | Constant flow mode | ||
| Output temperature coefficient TCS | -0.27 | -0.22 | -0.17 | %FS /℃ | Constant pressure mode | |
| -0.05 | ±0.02 | 0.05 | %FS /℃ | Constant flow mode | ||
| resistance temperature coefficie-nt | 1500 | 2000 | 2500 | ppm /℃ | ||
| stability | 0.2 | %FS /Y | ||||
| Stress hysteresis | - | 0.05 | 0.1 | %FS | ||
| Overload pressure | 3× | |||||
| working temperature | -40 | - | 125 | ℃ | ||
| storage temperature | -40 | - | 150 | ℃ | ||
| If not specified, all values in this table are tested at voltage 5 Vdc and temperature 25 ± 3℃ | ||||||
The CPG series pressure sensor is a MEMS-based device with an all-silicon structure, designed to provide accurate pressure measurements across a range of -100 kPa to 700 kPa. It exhibits a linear relationship between the applied pressure and the output voltage, making it suitable for a variety of applications. This sensor is engineered for low cost and high long-term reliability, ideal for use in home appliances, medical equipment, sports, and industrial pressure measurement.
| Foot Position Number | Foot Position Definition (700 kPa) | Foot Position Definition (100 kPa) | Foot Position Definition (40 kPa) | Foot Position Definition (10 kPa) |
|---|---|---|---|---|
| 1 | VS + | GND | GND | Vout + |
| 2 | Vout - | Vs + | Vout + | Vs + |
| 3 | GND | NC | Vs + | NC |
| 4 | Vout + | NC | NC | NC |
| 5 | NC | Vout - | Vout - | Vout - |
| 6 | NC | Vout + | GND | GND |
Note: The SOP (Small Outline Package) has the same pin definition as the DIP (Dual In-line Package) pin.
|
|
5-10V DC MEMS Based Digital Output Pressure Sensor Images |